Cross-Platform Release Notes for Cisco IOS Release 12.0S
OL-1617-14 Rev. Q0
Caveats
Resolved Caveats—Cisco IOS Release 12.0(30)S
Conditions: This symptom is observed on a Cisco 12000 series when a large number of IPv6 routes
and 6PE labels are allocated.
Workaround: There is no workaround.
CSCef55463
Symptoms: When you configure vbr-nrt shaping on two or more PVCs that are defined under the
same physical ATM interface, one of the PVCs is subsequently unable to achieve the configured
vbr-nrt rate.
Conditions: This symptom is observed when a PA-A3-8E1IMA or PA-A3-8T1IMA port adapter is
installed in a Cisco 7xxx series and when the load is equal to or greater than the maximum
configured vbr-nrt rate on at least two PVCs.
Workaround: Configure vbr-nrt rates proportionally higher on each PVC. Enter the
transmit-priority 1 command on the PVC that must reach the guaranteed vbr-nrt. Doing so causes
the other PVC or PVCs to reach approximately 90 to 95 percent of the configured vbr-nrt rate.
CSCef56116
Symptoms: If the VLAN IDs on either side of an AToM cloud are different, the imposition side is
supposed to rewrite the VLAN ID with the remote value; this functionality does not work.
Conditions: This symptom is observed on a Cisco 12000 series that functions in an AToM
VLAN-to-VLAN environment.
Workaround: There is no workaround.
CSCef56327
Symptoms: You may not be able to configure the clock source line command during the
configuration of the SONET controller on a Cisco 7200 series in which a PA-MC-STM1 port adapter
is installed.
When you enter the clock source line command during the configuration of the SONET controller,
the output of the show running-config command indicates that the clock source is set to line.
However, the output of the show controllers sonet command indicates that the clock is set to
internal, and when you enter the show running-config command again, the output indicates this
time that the clock source is set to internal.
Conditions: This symptom is observed when the PA-MC-STM1 port adapter is connected
back-to-back via dark fiber to another PA-MC-STM1 port adapter.
Workaround: Enter the overhead s1byte ignore command on the SONET controller before you
configure the clock source.
CSCef56758
Symptoms: The cell packing command can not be configured under a vc-class template.
Conditions: This symptom is observed on a Cisco platform that runs a Cisco IOS release that is
listed in the “First Fixed-in Version” field at
http://www.cisco.com/cgi-bin/Support/Bugtool/onebug.pl?bugid=CSCdv49909. Releases that are
not listed in the “First Fixed-in Version” field at this location are not affected.
Workaround: There is no workaround.
CSCef57272
Symptoms: Even though the hw-module slot-number tcam compile no-merge command is
enabled, per-ACE counters in the output of the show access-lists command do not increment when
the same ACL is applied to more than one port.