Cross-Platform Release Notes for Cisco IOS Release 12.0S
OL-1617-14 Rev. Q0
Caveats
Resolved Caveats—Cisco IOS Release 12.0(30)S5
0x60BC47D0 0000000068 0000000008 0000000544 MLP bundle name
0x60BC47D0 0000000072 0000000001 0000000072 MLP bundle name
0x60BC47D0 0000000076 0000000001 0000000076 MLP bundle name
0x60BC47D0 0000000088 0000000018 0000001584 MLP bundle name
Conditions: This symptom is observed when two interfaces are configured in the same multilink
group or are bound to the same dialer profile.
Workaround: There is no workaround.
Resolved Caveats—Cisco IOS Release 12.0(30)S5
Cisco IOS Release 12.0(30)S5 is a rebuild of Cisco IOS Release 12.0(30)S. The caveats listed in this
section are resolved in Cisco IOS Release 12.0(30)S5 but may be open in previous Cisco IOS releases.
This section describes only severity 1, severity 2, and select severity 3 caveats.
Basic System Services
CSCsb98906
Symptoms: A memory leak may occur in the “BGP Router” process.
Conditions: This symptom is observed on a Cisco router that runs Cisco IOS Release 12.0(26)S6,
that is configured for BGP, and that has the /jointfilesconvert/415844/bgp regexp deterministic command enabled.
Workaround: Disable the /jointfilesconvert/415844/bgp regexp deterministic command.
Interfaces and Bridging
CSCsa46510
Symptoms: When you enter the microcode reload command, an error message similar to the
following and a traceback may be generated:
RSP-3-RESTART: interface Serial3/0/1/4:0, not transmitting -Traceback= 404436B4
4044DE10
Conditions: This symptom is observed on a Cisco 7500 that is configured with an E1, T1, E3, or T3
port adapter.
Workaround: There is no workaround.
CSCsc17534
Symptoms: Unicast packets are not CEF-switched on a VIP but are fast-switched on the RP.
Conditions: This symptom is observed on a Cisco router that has a VIP only when the ingress
interface is an ISL subinterface.
Workaround: There is no workaround.
CSCsc69537
Symptoms: A Cisco 12000 series may report incorrect ifIndex values in the NetFlow Data Export
(NDE) packets that are sent from a Gigabit Ethernet (GE) ISE line card. Flows that arrive via VLAN
subinterfaces may be reported as zero with the SNMP ifIndex or as the ifIndex of the physical GE
interface.
Conditions: This symptom is observed on a Cisco 12000 series that runs Cisco IOS
Release 12.0(30)S3 or a later release after you have reloaded the GE line card.