Seitenansicht 349
4-42
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 4 Error Messages
EID-5134 On node {0} the calculated gain is much greater than expected.
The wizard cannot operate under this condition.
Please call TAC for support.
Refer to the error message text.
EID-6001 One of the XC cards has failures or is missing. Check whether all the cross-connect cards
are installed and working.
EID-6002 One of the XC cards is locked. Unlock the cross-connect card.
EID-6003 The OSC termination could not be created.
This ring ID is already assigned.
Enter a new ID for the ring.
EID-6004 A system reset cannot be performed while a BLSR ring is
provisioned on the node.
Remove the BLSR from the node and
continue with the reset procedure.
EID-6005 The timing references could not be assigned.
- Only two DS1 or BITS interfaces can be specified.
- DS1 interfaces cannot be retimed and used as a reference.
- BITS-2 is not supported on this platform.
Refer to the error message text.
EID-6006 The timing references could not be assigned.
- An NE reference can only be used if the timing mode is LINE.
- A BITS reference can only be used if the timing mode is not
LINE.
- A Line reference can only be used if the timing mode is not
EXTERNAL.
Refer to the error message text.
EID-6008 SF BER and SD BER are not provisionable on the protect line
of a protection group.
Refer to the error message text.
WID-6009 If autoadjust GFP buffers is disabled, GFP buffers available
must be set to an appropriate value based on the distance
between the circuit endpoints.
Refer to the warning message text.
WID-6010 If auto detection of credits is disabled, credits available must be
set to a value less than or equal to the number of receive credits
on the connected FC endpoint.
Refer to the warning message text.
WID-6011 Ingress idle filtering should be turned off only when required to
operate with non-Cisco Fibre Channel/FICON-over-SONET
equipment.
Refer to the warning message text.
EID-6012 The retiming configuration could not be changed because there
are circuits on this port.
You cannot change the timing configuration
on this port unless the circuits on this port
are deleted.
EID-6013 The NTP/SNTP server could not be changed.
{1}
Refer to the error message text.
EID-6014 The operation failed because the reference state is OOS. Change the Out-of-service state to Active.
EID-6015 The distance extension cannot be disabled if the port media
type is FICON 1Gbps ISL or FICON 2Gbps ISL.
Refer to the error message text.
EID-6016 The card mode cannot be changed to Fibre Channel Line Rate
if the port media type is FICON 1Gbps ISL or FICON 2Gbps
ISL.
Refer to the error message text.
Table 4-1 Error Messages (continued)
Error/Warning
ID Error/Warning Message Description
Seitenansicht 349