2-84
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
The Inhibit Switch To Protect Request on Equipment condition occurs on traffic cards when the ability
to switch to protect has been disabled. If the port is part of a 1+1 protection scheme, traffic remains
locked onto the working system.
Clear the INHSWPR Condition
Step 1 If the condition is raised against a 1+1 port, complete the “Initiate a 1+1 Manual Switch Command”
procedure on page 2-157.
Step 2 If the condition does not clear, log into the Cisco Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.119 INHSWWKG
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA) for ONS 15310-MA
SONET Logical Object: EQPT
The Inhibit Switch To Working Request on Equipment condition occurs on ONS 15310-MA traffic cards
when the ability to switch to working has been disabled. If the card is part of a 1+1 protection scheme,
traffic remains locked onto the protect system.
Step 1 If the condition is raised against a 1+1 port, complete the “Initiate a 1+1 Manual Switch Command”
procedure on page 2-157.
Step 2 If the condition does not clear, log into the Cisco Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.120 INTRUSION-PSWD
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: NE
The Security Intrusion Incorrect Password condition occurs after a Superuser attempts a settable number
of unsuccessful logins, a login with an expired password, or an invalid password. The alarmed user is
locked out of the system, and INTRUSION-PSWD condition is raised. This condition is only shown in
Superuser login sessions, not in login sessions for lower-level users. The INTRUSION-PSWD condition
is automatically cleared when a settable lockout timeout expires, or it can be manually cleared in CTC
by the Superuser if lockout is permanent.
Clear the INTRUSION-PSWD Condition
Step 1 In node view, click the Provisioning > Security tabs.
Step 2 Click Clear Security Intrusion Alarm.