4-5
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 4 Error Messages
EID-2013 The circuit creation failed.
The circuit creation cannot proceed due to changes in the
network which affected the circuit(s) being created.
The dialog box will close. Please try again.
Refer to the error message text.
EID-2014 No circuit(s) were selected.
{0}
You must select a circuit to complete this
function.
EID-2015 The circuit {0} cannot be deleted because it has one or more
rolls.
You must delete the rolls in the circuit
before deleting the circuit itself.
EID-2016 The circuit deletion failed. CTC could not delete the tunnel as there are
circuits that use the tunnel.
EID-2017 An error occurred while mapping the circuit.
{0}
There was an error mapping the circuit.
EID-2018 The circuit roll failed.
The circuit must be in the DISCOVERED state in order to
perform a roll.
There was a failure in circuit roll. Change
the circuit state to DISCOVERED and
proceed.
EID-2019 The circuit roll failed.
Bridge and roll is not supported on DWDM circuits.
Refer to the error message text.
EID-2020 The circuit roll failed.
The two circuits must have the same direction.
Refer to the error message text.
EID-2021 The circuit roll failed.
The two circuits must have the same size.
Refer to the error message text.
EID-2022 The circuit roll failed.
A maximum of two circuits can be selected for a bridge and roll
operation.
Refer to the error message text.
EID-2023 CTC was unable to create a new user account. Refer to the error message text.
EID-2024 An error occurred during node selection. There was an error during node selection.
EID-2025 This feature cannot be used. Verify that each endpoint of this
circuit is running software that supports this feature.
Refer to the error or warning message text.
For example, this error is generated from
the node view Provisioning> WDM-ANS>
tabs to indicate that the selected ring type is
not supported by the endpoints of the
circuit. Another example is the
Provisioning> VLAN tabs in card view
(Ethernet card only), where it indicates that
the back-end spanning tree protocol (STP)
disabling is not supported.
EID-2026 The {0} request could not be applied.
{1}
Error occurred while attempting to switch a
path protection circuit away from a span.
EID-2027 An error occurred while deleting the circuit drop. CTC could not delete the circuit drop.
EID-2028 An error occurred while removing the circuit node. CTC could not remove the circuit node.
EID-2029 The requested operation is not supported. The task you are trying to complete is not
supported by CTC.
Table 4-1 Error Messages (continued)
Error/Warning
ID Error/Warning Message Description