2.7.168 MAN-REQ
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: STSMON, VT-MON
The Manual Switch Request condition occurs when a user initiates a Manual switch request on an OC-N
port. Clearing the Manual switch clears the MAN-REQ condition. You do not need to clear the switch if
you want the manual switch to remain.
Clear the MAN-REQ Condition
Step 1 Complete the “Initiate a 1+1 Manual Switch Command” procedure on page 2-157.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.169 MANRESET
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: EQPT
A User-Initiated Manual Reset condition occurs when you right-click a card in CTC and choose Reset.
Note MANRESET is an informational condition and does not require troubleshooting.
2.7.170 MANSWTOINT
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: NE-SREF
The Manual Switch To Internal Clock condition occurs when the NE timing source is manually switched
to an internal timing source.
Note MANSWTOINT is an informational condition and does not require troubleshooting.
2.7.171 MANSWTOPRI
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)