4-35
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 4 Error Messages
EID-5002 The tunnel could not be restored and must be recreated
manually.
Refer to the error message text.
EID-5003 The circuit roll failed.
{0}
Refer to the error message text.
EID-5004 There is already one four-fiber {0} provisioned on the set of
nodes involved in {1}. The maximum number of four-fiber {0}
rings has been reached for that node.
There is already one 4F BLSR provisioned
on the set of nodes involved in the ring. The
maximum number of 4F BLSR rings has
been reached for that node.
WID-5005 A non-zero hold-off time can violate switching time standards,
and should only be used for a circuit with multiple path
selectors.
Refer to the warning message text.
WID-5006 Warning: A different secondary {0} node should only be used
for DRI or open-ended path protected circuits.
You should use different secondary end
point only for DRI or open-ended path
protected circuits.
WID-5007 If you change the scope of this view, the contents of this profile
editor will be lost.
Refer to the warning message text.
WID-5008 Please ensure that all the protection groups are in proper states
after the cancellation.
Refer to the warning message text.
WID-5009 The circuit {0} is not upgradable.
No {1} capable {2}s are available at the node {3}.
No VT capable STSs are available at the
node.
EID-5010 The domain name already exists. Refer to the error message text.
EID-5011 The domain name cannot exceed {0} characters. You may have reached the maximum
number of characters.
WID-5012 The software load on {0} does not support the addition of a
node to a 1+1 protection group.
Refer to the warning message text.
EID-5013 {0} does not support the bridge and roll feature. Please select a
different port.
The specified port does not support Bridge
and Roll.
EID-5014 An automatic network layout is already in progress.
Please wait for it to complete before running it again.
You must for the automatic network layout
to complete before running it again.
WID-5015 {0} cannot be applied to {1}. You cannot apply the admin state operation,
specified by {0}, to port count, specified by
{1}.
EID-5016 An error occurred while attempting to provision the {0}.
{1}
CTC encountered an error while
provisioning the card.
EID-5017 Provisioning could not be rolled back. The {0} might be left in
an INCOMPLETE state and should be manually removed.
You may have to remove the BLSR
manually as it was left incomplete.
EID-5018 {0} is a(n) {1} node and cannot be added to a(n) {2} network. You cannot add the node {0} of type {1} to
the host node of type {2}. This prevents you
from hosting both SONET and SDH nodes
in the same session.
Table 4-1 Error Messages (continued)
Error/Warning
ID Error/Warning Message Description