Seitenansicht 172
2-43
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
2.7.42 CONTBUS-CLK-A
Default Severity: Minor (MN), Non-Service-Affecting (NSA) for ONS 15310-MA
SONET Logical Object: EQPT
An Inbound Interconnection Timing Control Bus 1 Failure alarm on the Slot 3 CTX2500 card occurs if
the timing signal from the Slot 4 CTX2500 card has an error. If the Slot 3 CTX2500 card and all other
cards on the shelf raise this alarm, the alarm processor on the Slot 4 CTX2500 card clears the alarm on
the other cards and raises this alarm against the Slot 3 CTX2500 card only.
Clear the CONTBUS-CLK-A Alarm
Step 1 If a single traffic card is reporting the alarm and it is part of a path protection configration, complete the
“Initiate a Force Switch for All Circuits on a Path Protection Span” procedure on page 2-160 procedure.
If the traffic card is part of a 1+1 protection group, complete the “Clear a 1+1 Force or Manual Switch
Command” procedure on page 2-158.
Step 2 Complete the appropriate procedure in the “2.10.3 Physical Card Reseating and Replacement” section
on page 2-163 for the reporting card.
Step 3 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1-800-553-2447).
Step 4 If traffic was manually switched in a 1+1 protection group, revert traffic to the original port by
completing the “Initiate a 1+1 Protection Port Force Switch Command” procedure on page 2-157. If
traffic was manually switched in a path protection configration, revert traffic to the original path by
completing the “Clear an External Switching Command on a Path Protection Span” procedure on
page 2-161.
2.7.43 CONTBUS-CLK-B
Default Severity: Minor (MN), Non-Service-Affecting (NSA) for ONS 15310-MA
SONET Logical Object: EQPT
An Inbound Interconnection Timing Control Bus 1 Failure alarm on the Slot 4 CTX2500 card occurs if
the timing signal from the Slot 3 CTX2500 card has an error. If the Slot 4 CTX2500 card and all other
cards on the shelf raise this alarm, the alarm processor on the Slot 3 CTX2500 card clears the alarm on
the other cards and raises this alarm against the Slot 4 CTX2500 card only.
Clear the CONTBUS-CLK-B Alarm
Step 1 If a single traffic port is reporting the alarm and it is part of a path protection configration, complete the
“Initiate a Force Switch for All Circuits on a Path Protection Span” procedure on page 2-160. If the
traffic port is part of a 1+1 protection group, complete the “Clear a 1+1 Force or Manual Switch
Command” procedure on page 2-158.
Note If the active CTX2500 card is reporting the alarm, shelf control should already have switched
off the card.