Seitenansicht 176
2-47
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
Caution Avoid soft-resetting multiple ONS 15310-MA cards at one time; doing so might cause an unexpected
traffic hit.
For the LED behavior, see the “2.9.2 Typical Card LED Activity During Reset” section on page 2-156.
Step 8 Verify that the reset is complete and error-free and that no new related alarms appear in CTC. A green
ACT/SBY LED indicates an active card. An amber ACT/SBY LED indicates a standby card.
Step 9 If the alarm does not clear, complete the “Remove and Reinsert (Reseat) a Card” procedure on
page 2-163 procedure for the standby Ethernet card.
Step 10 Complete the “Initiate an ONS 15310-MA 1:1 Card Switch Command” procedure on page 2-159 to
switch traffic back.
Step 11 If the alarm does not clear, complete the “Physically Replace a Card” section on page 2-163 procedure
for the reporting traffic card.
Step 12 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1 800 553-2447) in order to report a Service-Affecting (SA)
problem.
2.7.48 CTNEQPT-PBWORK
Default Severity: Critical (CR), Service-Affecting (SA)
SONET Logical Object: EQPT
The Interconnection Equipment Failure Working 15310-CL-CTX or CTX2500 card Payload Bus alarm
indicates a failure in the main payload bus between the 15310-CL-CTX or CTX2500 card and the
reporting Ethernet card. The controller card and the Ethernet or electrical card are no longer
communicating.
Clear the CTNEQPT-PBWORK Alarm
Step 1 If the alarm is reported against the 15310-CL-CTX or CTX2500 card, go to Step 4. If the Ethernet or
electrical traffic card shows the CTNEEQPT-PBWORK alarm, complete the “Soft- or Hard-Reset an
Ethernet or Electrical Card in CTC” procedure on page 2-162 for the card.
Step 2 Verify that the reset is complete and error-free and that no new related alarms appear in CTC. A green
ACT LED indicates an active card.
Step 3 If the alarm does not clear, complete the “Physically Replace a Card” procedure on page 2-163.
Caution Always use the supplied electrostatic discharge wristband when working with a powered ONS 15310-CL
or ONS 15310-MA.
Note When you replace a card with the identical type of card, you do not need to make any changes
to the database.