4-62
Cisco ONS 15454 and Cisco ONS 15327 TL1 Command Guide, R3.3
May 2002
Chapter 4 TL1 Command Components
Parameter Types
4.3.84 T3_MONTYPE
T3 monitor type
4.3.85 TACC_MODE
Test access mode
Table 4-117 T3_MONTYPE Values
T3_MONTYPE Values Description
CVL Coding Violation - Line
ESL Errored Second - Line
SESL Severely Errored Second - Line
Table 4-118 TACC_MODE Values
TACC_MODE
Values Description
LOOPE Indicates to split both the A and B paths, connect the line incoming from E direction
to the line outgoing in the E direction, and connect this looped configuration to the
FAD. The line outgoing in the F direction shall have a QRS connected, and the line
incoming from the F direction shall be terminated by the nominal characteristic
impedance of the line.
LOOPF Indicates to split both the A and B paths, connect the line incoming from F direction
to the line outgoing in the F direction, and connect this looped configuration to the
FAD. The line outgoing in the E direction shall have a QRS connected, and the line
incoming from the E direction shall be terminated by the nominal characteristic
impedance of the line.
MONE Indicates that a monitor connection is to be provided from the FAD to the A
transmission path of the accessed circuit.
MONEF Indicates that a monitor connection is to be provided from the FAD1 to a DFAD, or
the odd pair of a FAP, to the A transmission path and from FAD2 of the same DFAD,
or the even pair of a FAP, to the B transmission path of the accessed circuit.
MONF Indicates that a monitor connection is to be provided from the FAD to the B
transmission path of the accessed circuit.
SPLTA Indicates that a connection is to be provided from both the E and F sides of the A
transmission path of the circuit under test to the FAD and split the A transmission
path.
SPLTB Indicates that a connection is to be provided from both the E and F sides of the B
transmission path of the circuit under test to the FAD and split the B transmission
path.
SPLTE Indicates to split both the A and B paths and connect the E side of the accessed circuit
to the FAD. The line outgoing in the F direction shall have a QRS connected, and the
line incoming from the F direction shall have a QRS connected, and the line incoming
from the E direction shall be terminated by the nominal characteristic impedance of
the line.