4-31
Cisco ONS 15454 and Cisco ONS 15327 TL1 Command Guide, R3.3
May 2002
Chapter 4 TL1 Command Components
Parameter Types
PS Occurrence of a protection switching event
PWR Internal hardware - Power failure (detected internal to NE)
PWR-A Internal hardware - Power failure (detected internal to NE) on slot 7
PWR-B Internal hardware - Power failure (detected internal to NE) on slot 11
PWRRESTART Recovery action - Powerfail Restart
RAI External failure - Incoming - Remote Alarm Indication
RCVR Internal hardware - Facility Termination equipment - Receiver failure
RCVR-MISS Facility termination equipment detects a missing receive cable on the
DS1 port or a possible mismatch of backplane equipment
RCVRY Recovery or service protection action has been initiated
RDI-L External failure - Outgoing - Remote Defect Indication - Line
RDI-P External failure - Outgoing - Remote Defect Indication - Path
RFI External failure - Incoming - Remote Failure Indication
RFI-L External failure - Incoming - Remote Failure Indication - Line
RFI-P External failure - Incoming - Remote Failure Indication - Path
RFI-V Upstream failure has occurred at the VT layer
RFLOWCTL Receive pause frames Threshold crossing alert
RING-MISMATCH Procedural Error - Mis-connected Ring
RING-SEGMENT Ring Is Segmented
RING-SW-EAST Ring switch is active on the East side
RING-SW-WEST Ring switch is active on the West side
RMON-ALARM An RMON Alarm
RMON-RESET RMON histories and alarms have been reset due to chipset reboot
ROVERSUB Receive packets dropped - internal congestion Threshold crossing
alert
SD Facility has passed BER Threshold for Signal Degrade
SD-L BER threshold exceeded for Signal Degrade - Line
SD-P BER threshold exceeded for Signal Degrade - Path
SEF External failure - Incoming - Severely Errored Frame
SF Facility has passed BER threshold for Signal Failure
SF-L BER threshold exceeded for Signal Failure - Line
SF-P BER threshold exceeded for Signal Failure - Path
SFTWDOWN Recovery action - Software download in progress
SFTWDOWN-FAIL Software Download Failed
SLMF External failure - Incoming - Signal Label Mismatch Failures -
SONET
SNTP-HOST SNTP host not alive condition
Table 4-46 CONDITION Values (continued)
CONDITION Values Description