4 Module Mode Commands
62 4025561
Rev
A
Use Exit to leave Module mode, or Logout to exit the CLI interface
All keywords and parameters are caseless. That is, MoDuLe == MODULE == module
Module Commands:
alarm [parameters]
Use the 'alarm' command to show all the current alarms. This command
works in all modes. Using the optional parameter 'domain' is the same
as not using any parameter. However, using the optional parameter
'module' will display only the alarms for the currently selected module.
chassis <chassis_range> [slot [slot_range]]
Use the 'chassis' command to specify the desired chassis number.
The <chassis_range> parameter can be either a specific chassis number
between 0 and 99, or it can be '*' to indicate the wildcard chassis
selection, or it can be a range of chassis numbers. Specify a range of
chassis in the form '[DIGITS - DIGITS]' such as '[5 - 15]'.
The 'chassis' command can be optionally followed by the slot command
on the same input line.
exit
Use the 'exit' command to return to CLI mode. This command must be
used before entering ICIM or TERMINAL mode.
info <parameter> <subparameters>
Use the 'info' command to display one or more module parameter values.
Any number of available parameters can be requested with the same command.
The <parameter> field can be either alarm, control, monitor or module.
Each has a different set of <subparameters>. Following are examples:
X/Y MODULE> info alarm <name> <alarm_param>
where <name> is the actual alarm name such as Enable. Wildcards are
allowed. For example, LasTemp* will select LasTempA and LasTempB. The
following values are allowed for alarm_param:
hysteresis - The alarm threshold hysteresis value
index - The alarm number, starting at 1, in the list of
alarms
label - The name of the alarm
limitadjust - Specifies whether the alarm has adjustable
threshold values
majorhigh - The high critical alarm threshold value; must be
less than or equal to the upper limit for this
alarm
majorlow - The low critical alarm threshold value; must be
greater than or equal to the lower limit for this
alarm
minorhigh - The high non-critical alarm threshold value
minorlow - The low non-critical alarm threshold value
nominal - The alarm nominal value
rangehi - The upper limit for this alarm threshold
rangelo - The lower limit for this alarm threshold
type - The alarm type (1, 2 & 7 are adjustable)
value - The current alarm state
X/Y MODULE> info control <name> <control_param>
where <name> is the actual control name such as Enable. Wildcards are
allowed. For example, Service* will select ServiceA and ServiceB. The
following values are allowed for control_param:
index - The control number, starting at 1, in the list of
controls
label - The name of the control
rangehi - The upper limit for this control
rangelo - The lower limit for this control
rangestep - The smallest increment allowed for the control
statenames - The list of symbolic control values
type - The control type: D(igital), F(loat), B(oolean),
S(tate)
units - The units for the control
value - The current control setting