info alarm
4025561 Rev
53
Detail parameter Description
Type Alarm type (types 1, 2, and 7 are adjustable).
Value Alarm state.
Access Rights Required
Read, ReadWrite, or Admin
Example
The following sample dialog illustrates the use of the info alarm command to view
the thresholds of a post-amplifier output power alarm. Note that these thresholds
are relative to the nominal alarm value.
02/05 MODULE> info alarm outpwra majorhigh minorhigh minorlow majorlow
hysteresis nominal
MODID NAME MAJORHIGH MINORHIGH MINORLOW MAJORLOW HYSTERESIS NOMINAL
02/05 OutPwrA 1 0.7 -0.7 -1 0.1 17.7
SUCCESS!
02/05 MODULE>