Cisco IOSSoftware Configurationforthe Cisco12000Series One-PortChannelized OC-12/STM-4(DS1/E1)ISE Line
Verifying and Monitoring Configurations with Show Commands
51
Cisco IOS Release 12.0(27)S1
The show controllers sonet slot/port brief command shows limited information for a SONET port.
Router# show controllers sonet 2/0 brief
SONET 2/0 is up. (Configured for Locally Looped) Hardware is GSR 1 port ISE OC12
(channelized)
Applique type is Channelized OCx interface
Clock Source is Line, AUG mapping is AU4.
Medium info:
Type: SDH, Line Coding: NRZ, Line Type: Short SM
Regenerator Section:
LOF = 0 LOS = 0 BIP(B1) = 0
Multiplex Section:
AIS = 0 RDI = 0 REI = 0 BIP(B2) = 0
Active Defects: None
Active Alarms: None
Alarm reporting enabled for: SF SLOS SLOF B1-TCA B2-TCA B3-TCA
BER thresholds: SF = 10e-3 SD = 10e-6
TCA thresholds: B1 = 10e-6 B2 = 10e-6 B3 = 10e-6
High Order Path:
PATH 1:
AIS = 0 RDI = 0 REI = 15 BIP(B3) = 11
LOP = 0 PSE = 4 NSE = 0 NEWPTR = 1
LOM = 0 PLM = 0 UNEQ = 0
Active Defects: None
S1S0 = 02, C2 = 02
PATH TRACE BUFFER : STABLE
CRC-7: 0xF2 OK
52 6F 75 74 65 72 33 2F 30 2F 31 00 00 00 00 Router3/0/1....
STM1.AU4 3/0.1 is up. Hardware is GSR 1 port ISE OC12 (channelized)
Applique type is C12 in TUG-3 in AU-4
AU-4 1, TUG-3 1, TUG-2 1, E1 1 (C-12 1/1/1/1) is up
timeslots: 1-31
No alarms detected.
Framing is crc4, Clock Source is Internal
BERT test result (running)
Test Pattern : 2^15, Status : Sync, Sync Detected : 1
Interval : 5 minute(s), Time Remain : 2 minute(s)
Bit Errors (since BERT started): 0 bits,
Bits Received (since BERT started): 311 Mbits
Bit Errors (since last sync): 0 bits
Bits Received (since last sync): 311 Mbits
AU-4 1, TUG-3 1, TUG-2 1, E1 2 (C-12 1/1/1/2) is up
timeslots: 1-31
No alarms detected.
Framing is crc4, Clock Source is Internal
AU-4 1, TUG-3 1, TUG-2 1, E1 3 (C-12 1/1/1/3) is up
timeslots: 1-31
No alarms detected.
Framing is crc4, Clock Source is Internal
AU-4 1, TUG-3 1, TUG-2 2, E1 1 (C-12 1/1/2/1) is up
timeslots: 1-31
No alarms detected.
Framing is crc4, Clock Source is Internal
Kommentare zu diesen Handbüchern