Cisco IOS SoftwareConfiguration for theCisco 12000 SeriesOne-Port Channelized OC-12/STM-4(DS1/E1) ISE Line
How to Configure Layer 1 Features
10
Cisco IOS Release 12.0(27)S1
Step 4
description
string
Example:
Router(config-controller)# description E1T1Card
(Optional). You can add a description of up to 80 characters
about a controller to help you remember what is attached to
it. The description is intended solely as a comment about
the use of the controller. The description will appear in the
output of the following commands:
• show configuration
• show system running config
• show controllers.
Step 5
report {all |
event
}
Example:
Router(config-controller)# report {all |
event
}
(Optional). Enable reporting of selected alarm and signal
events.
The following alarm and signal events are enabled and
reported by default:
• sf-ber
• slos
• slof
• b1-tca
• lais
• b2-tca
Enable reporting for the alarm and signal events
individually, or use the all keyword to enable all of the
available alarm and signal events.
Step 6
threshold
type value
Example:
Router(config-controller)# threshold all
(Optional). Set threshold values for the BER Threshold
Crossing Alarms. For further information, see the document
Bit Error Rate Testing on Channelized Line Cards in Cisco
12000 Series Internet Routers at the following URL:
http://www.cisco.com/univercd/cc/td/doc/product/software
/ios120/120newft/120limit/120s/120s21/bert.htm
Step 7
overhead s1s0
number
Example:
Router(config-controller)# overhead s1s0 2
(Optional). Sets S1 and S0 overhead bits. Legal values are
0 to 3. The default is 0 for SONET and 2 for SDH framing.
The values for these bits are set automatically with frame
type. Change the values only to ensure operability with
older or nonstandard equipment, or to ensure operability if
the bit values in the network are other than the defaults. For
example, SDH equipment in Australia might use 1 as the
SDH value.
The S1 and S0 bits are located in the H1 Administrative
Unit (AU) pointer byte, bit locations 5 and 6.
Step 8
overhead j0
number
Example:
Router(config-controller)# overhead j0 82
(Optional). Sets identifier of transmitting equipment (0 to
255). Default is 1.
Section trace is a maintenance feature of SONET. One byte
(J0) of the Section overhead associated with each SONET
frame is used to carry information identifying the
transmitting equipment.
Command or Action Purpose
Kommentare zu diesen Handbüchern