Seitenansicht 169
11-38
Cisco Security Appliance Command Line Configuration Guide
OL-6721-01
Chapter 11 Configuring Failover
Configuring Failover
Logical Update Queue Information
Cur Max Total
Recv Q: 0 1 1895
Xmit Q: 0 0 1940
The following is sample output from the show failover group command for Active/Active Failover. The
information displayed is similar to that of the show failover command, but limited to the specified
group. Table 11-5 provides descriptions for the information shown.
hostname# show failover group 1
Last Failover at: 04:09:59 UTC Jan 4 2005
This host: Secondary
State: Active
Active time: 186 (sec)
admin Interface outside (192.168.5.121): Normal
admin Interface inside (192.168.0.1): Normal
Other host: Primary
State: Standby
Active time: 0 (sec)
admin Interface outside (192.168.5.131): Normal
admin Interface inside (192.168.0.11): Normal
Stateful Failover Logical Update Statistics
Status: Configured.
RPC services 0 0 0 0
TCP conn 33 0 0 0
UDP conn 0 0 0 0
ARP tbl 12 0 0 0
Xlate_Timeout 0 0 0 0
GTP PDP 0 0 0 0
GTP PDPMCB 0 0 0 0
Table 11-5 Show Failover Display Description
Field Options
Failover
On
Off
Failover Unit Primary or Secondary.
Failover LAN Interface Displays the logical and physical name of the failover link.
Unit Poll frequency Displays the number of seconds between hello messages sent to the
peer unit and the number of seconds during which the unit must receive
a hello message on the failover link before declaring the peer failed.
Interface Poll frequency n seconds
The number of seconds you set with the failover polltime interface
command. The default is 15 seconds.
Interface Policy Displays the number or percentage of interfaces that must fail before
triggering failover.