Chapter 11 Configuring Failover
Understanding Failover
Failover Triggers
The unit can fail if one of the following events occurs:
The unit has a hardware failure or a power failure.
The unit has a software failure.
Too many monitored interfaces fail.
The no failover active command is entered on the active unit or the failover active command is
entered on the standby unit.
Failover Actions
In Active/Standby failover, failover occurs on a unit basis. Even on systems running in multiple context
mode, you cannot fail over individual or groups of contexts.
Table 11-1 shows the failover action for each failure event. For each failure event, the table shows the
failover policy (failover or no failover), the action taken by the active unit, the action taken by the
standby unit, and any special notes about the failover condition and actions.
Table 11-1 Failover Behavior
Failure Event Policy Active Action Standby Action Notes
Active unit failed (power or
hardware)
Failover n/a Become active
Mark active as
failed
No hello messages are received on
any monitored interface or the
failover link.
Formerly active unit recovers No failover Become standby No action None.
Standby unit failed (power or
hardware)
No failover Mark standby as
failed
n/a When the standby unit is marked as
failed, then the active unit will not
attempt to fail over, even if the
interface failure threshold is
surpassed.
Failover link failed during
operation
No failover Mark failover
interface as failed
Mark failover
interface as failed
You should restore the failover link
as soon as possible because the
unit cannot fail over to the standby
unit while the failover link is down.
Failover link failed at startup No failover Mark failover
interface as failed
Become active If the failover link is down at
startup, both units will become
active.
State link failed No failover No action No action State information will become out
of date, and sessions will be
terminated if a failover occurs.
Interface failure on active unit
above threshold
Failover Mark active as
failed
Become active None.
Interface failure on standby
unit above threshold
No failover No action Mark standby as
failed
When the standby unit is marked as
failed, then the active unit will not
attempt to fail over even if the
interface failure threshold is
surpassed.