Cisco 600 Series Installation and Operation Guide
78-11190-01
Chapter 5 Configuration Procedures for the Cisco 67x CPE Devices
Configure the WAN Ports and ATM Virtual Connections
To set the maximum number of VCs, enter:
cbos# set interface wan0 maxvcs n
where
n
is between 1 and 8.
Table 5-2 shows the valid ranges for the VPI and VCI addresses.
Note
In CBOS version 2.3 or earlier, the VPI count is 1 to 4. In later
versions, the VPI count is 1 to 8.
Changing VPI Settings
Step 1
To make sure the wan0-0 connection remains closed during configuration, enter:
set interface wan0-0 disable
Step 2
To set the VPI number to 2, enter:
set interface wan0-0 vpi 2
Note
If you try to enter the command
set interface wan0-1
on a
connection that is already open, the system prompts you to
close that connection before you change the VPI setting.
Close the connection by entering
set interface wan0-1
close
.
Table 5-2 VPI/VCI Address Ranges
Maximum VCs VPI Range VCI Range
10-3 0-63
20-3 0-63
40-3 0-63
80-3 0-63