Cisco 675E Betriebsanweisung Seite 13

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 50
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 12
5-13
Cisco 600 Series Installation and Operation Guide
78-11190-01
Chapter 5 Configuration Procedures for the Cisco 67x CPE Devices
Configure the WAN Ports and ATM Virtual Connections
To set the maximum number of VCs, enter:
cbos# set interface wan0 maxvcs
n
where n is between 1 and 8.
Table 5-2 shows the valid ranges for the VPI and VCI addresses.
Note In CBOS version 2.3 or earlier, the VPI count is 1 to 4. In later
versions, the VPI count is 1 to 8.
Changing VPI Settings
Step 1 To make sure the wan0-0 connection remains closed during configuration, enter:
set interface wan0-0 disable
Step 2 To set the VPI number to 2, enter:
set interface wan0-0 vpi 2
Note If you try to enter the command set interface wan0-1 on a
connection that is already open, the system prompts you to
close that connection before you change the VPI setting.
Close the connection by entering set interface wan0-1
close.
Table 5-2 VPI/VCI Address Ranges
Maximum VCs VPI Range VCI Range
1 0-3 0-63
2 0-3 0-63
4 0-3 0-63
8 0-3 0-63
Seitenansicht 12