20
Installing Field-Replaceable Units in Cisco 3745 Routers
78-14308-02
Replacing Cisco 3745 Chassis Power Supplies
Figure 13 Wire Connections for DC Input
Step 5 Install the plastic cover over the terminals.
Warning
The safety cover is an integral part of the product. Do not operate the unit without the safety cover
installed. Operating the unit without the cover in place will invalidate the safety approvals and pose
a risk of fire and electrical hazards. To see translations of the warnings that appear in this
publication, refer to the
Regulatory Compliance and Safety Information
document that accompanied
this device.
Warning
After wiring the DC power supply, remove the tape from the circuit breaker switch handle and
reinstate power by moving the handle of the circuit breaker to the ON position. To see translations of
the warnings that appear in this publication, refer to the
Regulatory Compliance and Safety
Information
document that accompanied this device.
Warning
Voltages might be present on the DC-input power supply terminals. Turn off the power source circuit
breaker and remove the power supply before accessing the terminals. To see translations of the
warnings that appear in this publication, refer to the
Regulatory Compliance and Safety Information
document that accompanied this device.
Step 6 Secure the wires using cable ties.
Warning
Secure all power cabling when installing this unit to avoid disturbing field-wiring connections. To
see translations of the warnings that appear in this publication, refer to the
Regulatory Compliance
and Safety Information
document that accompanied this device.
72079
Negative
Positive
Ground