18
Installing Field-Replaceable Units in Cisco 3745 Routers
78-14308-02
Replacing Cisco 3745 Chassis Power Supplies
Step 5 Tighten the two captive screws located inside the access door. (See Figure 6 for reference.)
Step 6 Place the router so the rear panel is facing toward you.
Step 7 Install the two retaining screws at the rear of the chassis. (See Figure 5 for reference.)
Step 8 If you are installing a PWR-3745-DC-U= universal DC power supply, apply the input voltage label
(supplied) over the existing input voltage label on the rear of the chassis.
Step 9 Connect the network interface cables on the rear panel.
Note Cisco 3745 routers require a reliable earth ground connection using a ground lug and AWG 16 (13mm
2
)
wire. If your router does not have an earth ground connection, refer to the Cisco 3745 Quick Start Guide
that was provided with your router, or refer to the Cisco 3700 Series Hardware Installation Guide on
Cisco.com, for instructions on installing an earth ground.
Step 10 Connect your router to the appropriate AC or DC power source.
If your router uses DC power, proceed to the “Connecting DC-Input Power” section.
If your router uses AC power, connect the AC power cord. The following warning applies to AC power.
Warning
Thisproduct reliesonthe building'sinstallation for short-circuit (overcurrent)protection. Ensure that
the protective device is rated not greater than:
15A, 120VAC (10A, 240VAC)
Toseetranslations of thewarningsthat appear inthispublication, refer to theRegulatory Compliance
and Safety Information document that accompanied this device.
Connecting DC-Input Power
This section explains how to connect DC power to Cisco 3745 routers.
Warning
Thisproductrelies on the building’sinstallationforshort-circuit (overcurrent)protection. Ensure that
the protective device is rated not greater than:
20A, 60VDC.
Toseetranslations of thewarningsthat appear inthispublication, refer to the
RegulatoryCompliance
and Safety Information
document that accompanied this device.
Note The installation must comply with the 2002 National Electric Code (NEC) and other applicable codes.
Warning
Use copper conductors only.To see translations of the warnings thatappear in this publication, refer
to the
Regulatory Compliance and Safety Information
document that accompanied this device.
Kommentare zu diesen Handbüchern