Installing Field-Replaceable Units in Cisco 3745 Routers
78-14308-02
Replacing Cisco 3745 Chassis Power Supplies
Wire and Terminal Requirements
Earlier model power supplies, PWR-3745-DC=, require copper wire, size AWG 14 to 16 (2.0 to
1.2 mm
2
), for the positive and negative connections and AWG 14 (2.0 mm
2
) minimum for the ground
connection. Use a spade lug, Molex part number 19099-0017 or equivalent, for these connections.
Later model power supplies, PWR-3745-DC-U=, require copper wire, size AWG 12 to 14 (3.0 to
2.0 mm
2
), for the positive and negative connections and AWG 12 (3.0 mm
2
) minimum for the ground
connection. For connecting AWG 12 wires, use a spade lug, Amp/Tyco part number 52961 or equivalent.
For connecting AWG 14 wires, use a spade lug, Molex part number 19099-0017 or equivalent.
Wiring Procedure
To connect the router to a DC power source, perform the following steps. If the DC input wires are
already prepared for termination, start with Step 3.
Step 1 Strip the wires to the appropriate length for the spade lugs. The strip length is 1/8 to 3/16 inch (3 to 5
mm) for Molex number 19073-0009 spade lugs.
Step 2 Crimp the spade lugs onto the DC power input wires.
Warning
When stranded wiring is required, use approved wiring terminations, such as closed-loop or
spade-type with upturned lugs. These terminations should be the appropriate size for the wires and
should clamp both the insulation and conductor. To see translations of the warnings that appear in
this publication, refer to the
Regulatory Compliance and Safety Information
document that
accompanied this device.
Step 3 Remove the plastic cover from the terminal block. Save it for reinstallation after you finish wiring.
Step 4 Connect the DC power input wires to the terminal block as shown in Figure 13 on page 20.
Warning
This warning appliesonly tounits equippedwith DC input powersupplies. Wire theDC powersupply
usingthe appropriatelugs atthewiringend.The properwiring sequenceisground toground, positive
topositive (line to L), and negative to negative (neutral to N). Note that the ground wire should always
be connected first and disconnected last. To see translations of the warnings that appear in this
publication, refer to the
Regulatory Compliance and Safety Information
document that accompanied
this device.
Caution Do not overtorque the terminal block contact screws. The recommended torque is 8.0 ± 0.5 in-lb
(0.93 ± 0.05 N-m).
Warning
Anexposed wirelead froma DC-inputpower sourcecan conductharmfullevelsofelectricity.Besure
that no exposed portion of the DC-input power source wire extends from the terminal block plug. To
see translations of the warnings that appear in this publication, refer to the
Regulatory Compliance
and Safety Information
document that accompanied this device.