Cisco 12012 Technical Information Seite 49

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 60
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 48
show environment
Cisco 12000 Series Gigabit Switch Routers 61
Slot # 5V MBUS 5V 48V AMP_48
(mv) (mv) (Volt) (Amp)
24 0 5096 3 0
26 5544 5144 47 3
Slot # Fan Information
16 Voltage 16V Speed slow: Main Fans Ok Power Supply fans Ok
Alarm Indicators
No alarms
Slot # Card Specific Leds
16 Mbus OK SFCs Failed
18 Mbus OK
19 Mbus OK
24 Input Failed
26 Input Ok
The following is sample output from the show environment table command for a Cisco 12012. The
show environment table command lists the warning, critical, and shutdown limits on your system
and includes the GRP card and line cards (slots 0-15), clock and scheduler cards (slots 16-17), switch
fabric cards (slots 18-20), and blowers.
Router# show environment table
Hot Sensor Temperature Limits (deg C):
Warning Critical Shutdown
GRP/GLC (Slots 0-15) 40 46 57
CSC (Slots 16-17) 46 51 65
SFC (Slots 18-20) 41 46 60
Inlet Sensor Temperature Limits (deg C):
Warning Critical Shutdown
GRP/GLC (Slots 0-15) 35 40 52
CSC (Slots 16-17) 40 45 59
SFC (Slots 18-20) 37 42 54
3V Ranges (mv):
Warning Critical Shutdown
Below Above Below Above Below Above
GRP/GLC (Slots 0-15) 3200 3400 3100 3500 3050 3550
CSC (Slots 16-17) 3200 3400 3100 3500 3050 3550
SFC (Slots 18-20) 3200 3400 3100 3500 3050 3550
5V Ranges (mv):
Warning Critical Shutdown
Below Above Below Above Below Above
GRP/GLC (Slots 0-15) 4850 5150 4750 5250 4680 5320
MBUS_5V Ranges (mv):
Warning Critical Shutdown
Below Above Below Above Below Above
GRP/GLC (Slots 0-15) 5000 5250 4900 5350 4750 5450
CSC (Slots 16-17) 4820 5150 4720 5250 4750 5450
SFC (Slots 17-20) 5000 5250 4900 5350 4750 5450
Blower Operational Range (RPM):
Top Blower:
Warning Critical
Below Below
Fan 0 1000 750
Fan 1 1000 750
Fan 2 1000 750
Seitenansicht 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 59 60