Command Reference
60
Release 11.2 GS
Table 3 describes the fields shown in the output and lists the equipment that is supported by each
environmental parameter. If an “NA” is listed in the field and the equipment is supported, it means
that the reading could not be obtained. Try the command again.
The following is sample output from the show environment all command for the Cisco 12008. Slots
0 through 7 are the line cards, slots 16 and 17 are the clock scheduler cards (the clock scheduler cards
control the fans), slots 18 through 20 are the switch fabric cards, and slots 24 and 26 are the power
supplies. The Cisco 12008 does not support slots 25, 27, 28, and 29. An “NA” in the table means
that no values was returned. In some cases it is because the equipment is not supported for that
environmental parameter (for example, the power supplies in slots 24 and 26 do not have a hot
sensor, so an NA is displayed).
Router# show environment all
Slot # Hot Sensor Inlet Sensor
(deg C) (deg C)
2 31.0 22.0
5 33.5 26.5
16 25.5 21.5
18 22.0 21.0
19 22.5 21.0
24 NA 29.5
26 NA 24.5
Slot # 3V 5V MBUS 5V
(mv) (mv) (mv)
2 3292 5008 5136
5 3292 5000 5128
16 3272 NA 5128
18 3300 NA 5128
19 3316 NA 5128
Table 3 Show Environment Field Descriptions
Field Description
Slot # Slot number of the equipment. On the Cisco 12012, slots 0 through 11 are the line
cards, slots 16 and 17 are the clock and scheduler cards, slots 18 through 20 are
the switch fabric cards, slots 24 through 27 are the power supplies, and slots 28
and 29 are the blowers.
3V (mv) Measures the 3-volt power supply on the card. The 3-volt power supply is on the
line cards, GRP card, clock and scheduler cards, and switch fabric cards.
5V (mv) Measures the 5-volt power supply on the card. The 5-volt power supply is on the
line cards, GRP card, and power supplies.
MBUS 5V (mv) Measures the 5-volt MBus on the card. The 5-volt MBus is on all equipment.
Hot Sensor (deg C) Measures the temperature at the hot sensor on the card. The hot sensor is on the
line cards, GRP card, clock and scheduler cards, switch fabric cards, and blowers.
Inlet Sensor (deg C) Measures the current inlet temperature on the card. The inlet sensor is on the line
cards, GRP card, clock and scheduler cards, switch fabric cards, and power
supplies.
48V (Volt) Measures the DC power supplies.
AMP_48 (Amp) Measures the AC power supplies.
Fan 0, Fan 1, Fan 2 Measures the fan speed in rotations per minute.