TANDBERG TANDBERG and Cisco CallManager
D13907.01
38
To verify that the Route Pattern was inserted you can look at the list of Route Patterns that are configured
in the CallManager (from the example below you see that there are several different route patterns that are
pointing at the same route list)
Note: The H.323 support in the CallManager is limited to H.323 version 2, because of this the calls
between the SCCP endpoints and the H.323 endpoints will be using H.261 or H.263 even thought both
endpoints support H.264 (H.264 is not supported in H.323 version 2)
The configuration of the routing rules and trunk between the CallManager and the Gatekeeper is now
completed and you should be able to place calls between the SCCP network and the H.323 network.