10-20
Cisco PIX Firewall and VPN
78-15033-01
Chapter 10 Using PIX Firewall Failover
Forcing Failover
Testing the Failover Functionality
Follow these steps to ensure failover works:
Step 1 Power up the standby unit.
Step 2 Test that your primary (active) unit is passing traffic as expected by using FTP (for example) to send a
file between hosts on different interfaces.
Step 3 Power up the standby unit, and wait for the configuration to sync.
Step 4 Power down the active unit to force a failover to the standby unit.
Step 5 Use FTP to send another file between the same two hosts.
Step 6 If the network test was successful, power on the primary unit. If the test was not successful, enter the
show
failover command to check the failover status.
Step 7 When you are finished, you can leave the secondary unit as active, or force the primary unit to be active
again by entering:
primary(config)# failover active
Forcing Failover
To force the standby unit to become active, enter:
On the active unit:
primary(config)# no failover active
On the standby unit:
secondary(config)# failover active
Disabling Failover
You can disable failover by entering the following command on the active unit:
primary(config)# no failover
This command is replicated to the standby unit, so that it also has failover disabled. To verify that
failover is off, enter the show failover command:
primary(config)# show failover
Xmit Q The status of the transmit queue.
Lan-based Failover is Active This field appears only when LAN-based failover is enabled.
interface name (n.n.n.n):
peer (n.n.n.n):
For the LAN failover link, the display shows the IP address currently
being used on each unit, as well as the condition of the link. See the
preceding interface description for a description of each condition.
Table 10-2 Show Failover Display Description (continued)
Field Options