Cisco Catalyst 4000 Access Gateway Module Installation and Configuration Note
OL-3008-01
Chapter 2 Installing the Access Gateway Module
Connecting the Voice and WAN Interface Modules
Connecting the 1-Port Multiflex Trunk Interface Modules
This section describes how to connect and verify the status of the 1-port multiflex trunk interface
modules (VWIC-1MFT-T1, VWIC-1MFT-E1, or VWIC-1MFT-G703).
Use the straight-through RJ-48C-to-RJ-48C cable that shipped with the AGM.
To connect the 1-port multiflex trunk interface module, perform these steps:
Step 1 Power off the AGM.
Step 2 Connect one end of the cable to the RJ-48C port of the module, as shown in Figure 2-16.
Step 3 Connect the other end of the cable to the RJ-48C wall jack at your site, as shown in Figure 2-16.
Figure 2-16 Connecting a 1-Port Multiflex Trunk Interface Module (VWIC-1MFT-T1)
Step 4
Power on the AGM.
Step 5 Verify that the CD LED is green, indicating that the module’s internal DSU/CSU is communicating with
the DSU/CSU at the T1 or E1 service provider’s CO.
VWIC
1MFT-T1
AL
LP
CD
CTRLR T1 0
SEE
MANUAL
BEFORE
INSTALLATION
T1 port
(RJ-48C)
T1 (RJ-48C)
wall jack
22158
Straight-through
RJ-48C-to-RJ-48C cable