Cisco AS5800 Spezifikationen Seite 189

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 334
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 188
5-11
Cisco AS5800 Operations, Administration, Maintenance, and Provisioning Guide
DOC-7810814=
Chapter 5 Maintenance
Replacement Procedures
Step 4 If you are using the optional AC-input power shelf, disconnect the monitor cable DB-9 connector from
the base of the filter module, as shown in Figure 5-9.
Figure 5-9 Filter Module Monitor Cable Connections
Note Figure 5-9 shows the location of the DB-9 connector, which is at the base of the
filter module. The safety cover normally covering the AC-input power shelf rear
panel has been removed to show the DB-25 connector, which you use to connect
the monitor cable from the filter module to the AC-input power shelf.
Caution The filter module weighs 5.5 lb (2.5 kg). Use both hands when removing or replacing the
filter module.
48V 48V
RTN
C
NC
NO
POWER
MISWIRE
C
NC
NO
POWER
MISWIRE
48V 48V
RTN
H11161
DB-9 cable
connector
DB-25 cable
connector
PEM
Filter module
AC-input power shelf
Seitenansicht 188
1 2 ... 184 185 186 187 188 189 190 191 192 193 194 ... 333 334

Kommentare zu diesen Handbüchern

Keine Kommentare