CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.19 MARCH 2, 2015 WWW.CISCO.COMCisco UCS B420 M3Blade Server

Seite 2 - CONTENTS

Cisco UCS B420 M3 Blade Server10CONFIGURING the SERVERSupported Configurations(1) Two-CPU Configuration Choose two identical CPUs from any one of the

Seite 3 - OVERVIEW

Cisco UCS B420 M3 Blade ServerCONFIGURING the SERVER11STEP 3 CHOOSE MEMORYThe standard memory features are: DIMMs— Clock speed: 1600 MHz— Ranks per D

Seite 4 - DETAILED VIEWS

Cisco UCS B420 M3 Blade Server12CONFIGURING the SERVERChoose DIMMs and Memory MirroringSelect the memory configuration and whether or not you want the

Seite 5

Cisco UCS B420 M3 Blade ServerCONFIGURING the SERVER13— When mixing different densities of 1600-MHz RDIMMs within a channel, memory will run at 1.5 V

Seite 6

Cisco UCS B420 M3 Blade Server14CONFIGURING the SERVERFor more information regarding memory, see DIMM and CPU Layout on page 37.Supported Configuratio

Seite 7

Cisco UCS B420 M3 Blade ServerCONFIGURING the SERVER15STEP 4 CHOOSE DISK DRIVES (OPTIONAL)The UCS B420 M3 can be ordered with or without drives. The B

Seite 8 - STEP 1 VERIFY SERVER SKU

Cisco UCS B420 M3 Blade Server16CONFIGURING the SERVERSupported Configurations Select 1, 2, 3, or 4 of the drives listed in Table 6. Notes When crea

Seite 9 - STEP 2 CHOOSE CPU(S)

Cisco UCS B420 M3 Blade ServerCONFIGURING the SERVER17STEP 5 CHOOSE ADAPTERSThe adapter offerings are: Cisco Virtual Interface Cards (VICs)Cisco-deve

Seite 10

Cisco UCS B420 M3 Blade Server18CONFIGURING the SERVER“Adapter 1,” “Adapter 2,” and “Adapter 3” refer to the UCSM naming convention for the adapter sl

Seite 11 - STEP 3 CHOOSE MEMORY

Cisco UCS B420 M3 Blade ServerCONFIGURING the SERVER19(1) 2-CPU System Configuration Select an adapter combination in accordance with Table 10. Not p

Seite 12 - ■ DIMM configuration rules:

Cisco UCS B420 M3 Blade Server2CONTENTSOVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3DETAIL

Seite 13

Cisco UCS B420 M3 Blade Server20CONFIGURING the SERVERNot populated Not populated Emulex or QLogic adapter20 GbFigure 16 on page 4920 GbFigure 28 on p

Seite 14

Cisco UCS B420 M3 Blade ServerCONFIGURING the SERVER21STEP 6 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL)Trusted Platform Module (TPM) is a computer chi

Seite 15

Cisco UCS B420 M3 Blade Server22CONFIGURING the SERVERSTEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDSDual SDHC flash card sockets are provided

Seite 16

Cisco UCS B420 M3 Blade ServerCONFIGURING the SERVER23STEP 8 ORDER INTERNAL USB 2.0 DRIVE (OPTIONAL)You may order one optional internal USB 2.0 drive.

Seite 17 - STEP 5 CHOOSE ADAPTERS

Cisco UCS B420 M3 Blade Server24CONFIGURING the SERVERSTEP 9 ORDER FLASH-BACKED WRITE CACHE (OPTIONAL)You may order an optional 1 GB flash-backed writ

Seite 18

Cisco UCS B420 M3 Blade ServerCONFIGURING the SERVER25STEP 10 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARESeveral operating systems and value-adde

Seite 19

Cisco UCS B420 M3 Blade Server26CONFIGURING the SERVERSLES-HGC-2S-5A SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr Support ReqdSLES-SAP-2S-1G-1A SLE

Seite 20

Cisco UCS B420 M3 Blade ServerCONFIGURING the SERVER27CIMC-SUP-BASE-K9 IMC Supervisor One-time Site Installation LicenseCIMC-SUP-TERM Acceptance of Ci

Seite 21

Cisco UCS B420 M3 Blade Server28CONFIGURING the SERVERSTEP 11 CHOOSE OPERATING SYSTEM MEDIA KIT (OPTIONAL)Choose the optional operating system media l

Seite 22

Cisco UCS B420 M3 Blade ServerCONFIGURING the SERVER29STEP 12 CHOOSE SERVICE and SUPPORT LEVELA variety of service options are available, as described

Seite 23

Cisco UCS B420 M3 Blade ServerOVERVIEW3OVERVIEWDesigned for enterprise performance and scalability, the Cisco® UCS B420 M3 Blade Server combines the a

Seite 24

Cisco UCS B420 M3 Blade Server30CONFIGURING the SERVERSMARTnet for UCS Hardware Only ServiceFor faster parts replacement than is provided with the sta

Seite 25

Cisco UCS B420 M3 Blade ServerCONFIGURING the SERVER31See Table 19.Partner Support Service for UCS Hardware Only provides customers with replacement p

Seite 26

Cisco UCS B420 M3 Blade Server32CONFIGURING the SERVERYou can choose a service listed in Table 21.Unified Computing Drive Retention ServiceWith the Ci

Seite 27

Cisco UCS B420 M3 Blade ServerCONFIGURING the SERVER33For more service and support information, see the following URL:http://www.cisco.com/en/US/servi

Seite 28

Cisco UCS B420 M3 Blade Server34CONFIGURING the SERVERSTEP 13 CHOOSE LOCAL KVM I/O CABLE* (OPTIONAL)The local KVM I/O cable ships with every UCS 5100

Seite 29

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL35SUPPLEMENTAL MATERIALSystem BoardA top view of the UCS B420 M3 system board is shown in Figure 5.

Seite 30

Cisco UCS B420 M3 Blade Server36SUPPLEMENTAL MATERIAL7 Diagnostics button (factory use only) 15 Supercap module for Flash-backed write cache8 1-GB Tra

Seite 31

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL37DIMM and CPU LayoutMemory is organized as shown in Figure 6.Figure 6 UCS B420 M3 Memory Organiz

Seite 32

Cisco UCS B420 M3 Blade Server38SUPPLEMENTAL MATERIALEach CPU controls four memory channels and 12 DIMM slots, as follows: CPU1: Channels A, B, C, an

Seite 33

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL39A quick reference for the recommended DIMM population order is shown in Table 25 and Table 26. CP

Seite 34

Cisco UCS B420 M3 Blade Server4DETAILED VIEWSDETAILED VIEWSBlade Server Front ViewFigure 2 is a detailed front view of the Cisco UCS B420 M3 Blade Ser

Seite 35 - SUPPLEMENTAL MATERIAL

Cisco UCS B420 M3 Blade Server40SUPPLEMENTAL MATERIALDIMM Physical LayoutThe overall DIMM and CPU physical layout is shown in Figure 7.Figure 7 DIMM

Seite 36

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL41Figure 8 shows how channels are physically laid out on the blade server. The DIMM slots are conti

Seite 37 - DIMM and CPU Layout

Cisco UCS B420 M3 Blade Server42SUPPLEMENTAL MATERIALNetwork ConnectivityThis section shows how the supported adapter card configurations for the B420

Seite 38 - DIMM Population Order

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL43Figure 9 shows the configuration for maximum bandwidth, where the following ports are routed to F

Seite 39

Cisco UCS B420 M3 Blade Server44SUPPLEMENTAL MATERIALVIC 1240 and Port Expander Adapter slot 1 is dedicated to the VIC 1240 adapter, and no other adap

Seite 40 - DIMM Physical Layout

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL45Connectivity Using the Cisco UCS 2208XP Fabric ExtenderThe connectivity options shown in Figure 1

Seite 41 - CPU 3CPU 2

Cisco UCS B420 M3 Blade Server46SUPPLEMENTAL MATERIALIn Figure 11, two ports from the VIC 1240 adapter are channeled to 2208XP Fabric Extender A and t

Seite 42 - Network Connectivity

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL47In Figure 13, four ports from the VIC 1280 are channeled to 2208XP Fabric Extender A and four are

Seite 43 - B420 M3 Blade Server

Cisco UCS B420 M3 Blade Server48SUPPLEMENTAL MATERIALIn Figure 15, two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are c

Seite 44 - VIC 1240 and Port Expander

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL49Figure 16 One Emulex or QLogic Adapter Installed in Adapter Slot 3 (other two slots empty)In Fi

Seite 45

Cisco UCS B420 M3 Blade ServerBASE SERVER STANDARD CAPABILITIES and FEATURES5BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 lists the capabilit

Seite 46

Cisco UCS B420 M3 Blade Server50SUPPLEMENTAL MATERIALIn Figure 18, two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are c

Seite 47

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL51In Figure 19, two ports from the VIC 1240 adapter are channeled to 2208XP Fabric Extender A and t

Seite 48

Cisco UCS B420 M3 Blade Server52SUPPLEMENTAL MATERIALIn Figure 21, four ports from the VIC 1280 are channeled to 2208XP Fabric Extender A and four are

Seite 49

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL53In Figure 22, two ports from the VIC 1240 adapter are channeled to 2208XP Fabric Extender A and t

Seite 50

Cisco UCS B420 M3 Blade Server54SUPPLEMENTAL MATERIALConnectivity using the Cisco UCS 2204XP Fabric ExtenderThe connectivity options shown in Figure 2

Seite 51

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL55In Figure 23, one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is chan

Seite 52

Cisco UCS B420 M3 Blade Server56SUPPLEMENTAL MATERIALIn Figure 25, two ports from the VIC 1280 are channeled to 2204XP Fabric Extender A and two are c

Seite 53

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL57In Figure 27, one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is chan

Seite 54

Cisco UCS B420 M3 Blade Server58SUPPLEMENTAL MATERIALIn Figure 29, there is no VIC 1240. Two Emulex or QLogic adapters are installed, one in each of t

Seite 55

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL59In Figure 30, one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is chan

Seite 56

Cisco UCS B420 M3 Blade Server6BASE SERVER STANDARD CAPABILITIES and FEATURESVideo The Cisco Integrated Management Controller (CIMC) provides video us

Seite 57

Cisco UCS B420 M3 Blade Server60SUPPLEMENTAL MATERIALIn Figure 31, one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is chan

Seite 58

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL61In Figure 33, two ports from the VIC 1280 are channeled to 2204XP Fabric Extender A and two are c

Seite 59

Cisco UCS B420 M3 Blade Server62SUPPLEMENTAL MATERIALIn Figure 34, one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is chan

Seite 60

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL63Connectivity using the Cisco UCS 2104XP Fabric ExtenderThe connectivity options shown in Figure 3

Seite 61

Cisco UCS B420 M3 Blade Server64SUPPLEMENTAL MATERIALIn Figure 35, one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is chan

Seite 62

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL65In Figure 37, one port from the VIC 1280 is channeled to 2208XP Fabric Extender A and one is chan

Seite 63

Cisco UCS B420 M3 Blade Server66SUPPLEMENTAL MATERIALIn Figure 39, there is no VIC 1240. In this case, an Emulex or QLogic adapter is installed in ada

Seite 64

Cisco UCS B420 M3 Blade ServerSUPPLEMENTAL MATERIAL67In Figure 41, one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is chan

Seite 65

Cisco UCS B420 M3 Blade Server68SUPPLEMENTAL MATERIALIn Figure 43, one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is chan

Seite 66

Cisco UCS B420 M3 Blade ServerTECHNICAL SPECIFICATIONS69TECHNICAL SPECIFICATIONSDimensions and WeightPower SpecificationsFor configuration-specific po

Seite 67

Cisco UCS B420 M3 Blade ServerCONFIGURING the SERVER7CONFIGURING the SERVERFollow these steps to configure the Cisco UCS B420 M3 Blade Server: STEP 1

Seite 68

Cisco UCS B420 M3 Blade Server70TECHNICAL SPECIFICATIONS

Seite 69 - TECHNICAL SPECIFICATIONS

Cisco UCS B420 M3 Blade Server8CONFIGURING the SERVERSTEP 1 VERIFY SERVER SKUVerify the product ID (PID) of the server as shown in Table 2.The base Ci

Seite 70

Cisco UCS B420 M3 Blade ServerCONFIGURING the SERVER9STEP 2 CHOOSE CPU(S)The standard CPU features are: Intel Xeon processor E5-4600 v2 or E5-4600 se