Seitenansicht 266
3-225
Cisco Wide Area Application Services Command Reference
OL-11817-01
Chapter 3 CLI Commands
snmp trigger
snmp trigger
To configure thresholds for a user-selected MIB object for monitoring purposes on a WAAS device, use
the snmp trigger EXEC command. Use the no form of this command to return the setting to the default
value.
snmp trigger {create mibvar [wildcard] [wait-time [absent [LINE | mibvar1 mibvar1] [LINE |
mibvar2 mibvar2] [LINE | mibvar3 mibvar3] [LINE] | equal
[absolute value [[LINE | mibvar1
mibvar1] [LINE | mibvar2 mibvar2] [LINE | mibvar3 mibvar3] [LINE] | delta value [LINE |
mibvar1 mibvar1] [LINE | mibvar2 mibvar2] [LINE | mibvar3 mibvar3] [LINE]] |
falling
[absolute value [LINE | mibvar1 mibvar] [LINE | mibvar2 mibvar2] [LINE | mibvar3
mibvar3] [LINE] | delta value [LINE | mibvar1 mibvar1] [LINE | mibvar2 mibvar2] [LINE |
mibvar3 mibvar3] [LINE]] | greater-than
[absolute value [LINE | mibvar1 mibvar1] [LINE |
mibvar2 mibvar2] [LINE | mibvar3 mibvar3] [LINE] | delta value [LINE | mibvar1 mibvar1]
[LINE | mibvar2 mibvar2] [LINE | mibvar3 mibvar3] [LINE]] | less-than
[absolute value
[LINE | mibvar1 mibvar1] [LINE | mibvar2 mibvar2] [LINE | mibvar3 mibvar3] [LINE] | delta
value [LINE | mibvar1 mibvar1] [LINE | mibvar2 mibvar2] [LINE | mibvar3 mibvar3] [LINE]]
| on-change
[[LINE | mibvar1 mibvar1][LINE | mibvar2 mibvar2] [LINE | mibvar3 mibvar3]
[LINE]] | present
[LINE | mibvar1 mibvar1] [LINE | mibvar2 mibvar2] [LINE | mibvar3
mibvar3] [LINE] | rising
[absolute value [LINE | mibvar1 mibvar1] [LINE | mibvar2 mibvar2]
[LINE | mibvar3 mibvar3] [LINE] | delta value [LINE | mibvar1 mibvar1] [LINE | mibvar2
mibvar2] [LINE | mibvar3 mibvar3] [LINE]]]] | delete mibvar}
Syntax Description create Configures a threshold for a MIB object.
mibvar Name of the MIB object that you want to monitor or the MIB object for
which you want to remove a monitoring threshold.
wildcard (Optional) Treats the specified MIB variable name as having a wildcard.
wait-time (Optional) Number of seconds, 60–600, to wait between trigger samples.
absent (Optional) Applies the absent existence test.
LINE (Optional) Description of the threshold being created.
mibvar1, mibvar2,
mibvar3
(Optional) Adds a MIB object to the notification.
mibvar1, mibvar2,
mibvar3
Name of the MIB object to add to the notification.
equal Applies the equality threshold test.
absolute (Optional) Uses an absolute sample type.
value (Optional) Absolute or delta value for sample.
delta Uses a delta sample type.
falling Applies the falling threshold test.
greater-than Applies the greater-than threshold test.
less-than Applies the less-than threshold test.
on-change Applies the changed existence test.
present Applies the present test.
rising Applies the rising threshold test.
delete Removes a threshold for a MIB object.