9-46
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.27 RTRV-ATTR-DWDM
9.6.27 RTRV-ATTR-DWDM
Command Types RTRV-ATTR-DWDM
Retrieves the notification codes for DWDM attributes.
Syntax Description
RTRV-ATTR-DWDM:[<tid>]:[aid]:<ctag>::[<ntfcncde>],[<condtype>][,,,];
<sid> <date> <time>
M <ctag> COMPLD
condtype Condition type identifies the type of alarm (maps to
cerent15216EdfaLogEventID). Possible condtype and
corresponding conddescr (in quotes) are:
LOS
(DWDM)
“Loss of Signal” (input power) alarm
(cerent15216EdfaAlarmLpin).
GAIN
(DWDM)
“Gain Out of Range” alarm (cerent15216EdfaAlarmGain).
LPOUT
(DWDM)
“Loss of Output Power” alarm (cerent15216EdfaAlarmLpout).
CTMP
(EQPT)
“Case Temperature Out of Range” alarm
(cerent15216EdfaAlarmCtmp).
DBBACKUP
(EQPT)
“Database Backup In Progress”
(cerent15216EdfaOpDbBackup).
DBRESTORE
(EQPT)
“Database Restore In Progress”
(cerent15216EdfaOpDbRestore).
LCRNT1
(EQPT)
“Excessive Pump1 Current” alarm
(cerent15216EdfaAlarmLcrnt1).
LCRNT2
(EQPT)
“Excessive Pump2 Current” alarm
(cerent15216EdfaAlarmLcrnt2).
LTMP 1
(EQPT)
“Excessive Pump1 Temperature” alarm
(cerent15216EdfaAlarmLtmp1).
LTMP 2
(EQPT)
“Excessive Pump2 Temperature” alarm
(cerent15216EdfaAlarmLtmp2).
PWRBUSA
(EQPT)
“Power Bus A (voltage) Alarm”
(cerent15216EdfaAlarmPowerBusA).
PWRBUSB
(EQPT)
“Power Bus B (voltage) Alarm”
(cerent15216EdfaAlarmPowerBusB).
SFTWDOWN
(EQPT)
“Software Download In Progress” (cerent15216EdfaOpLoad).
ALL Any or all of the above.
NULL Defaults to ALL.
Table 9-32 RTRV-ATTR-ALL Syntax Description (continued)
Parameter Syntax Description
Seitenansicht 209