Specifications for the MCU Module
Tables 3–5 provide specifications for the MCU module.
Table 3
MCU Module Specifications
LAN Interface
100BASE-T (10/100), RJ-45
Serial Port
EIA-232, DB-9
Protocols
H.323, T.120
Video Coding
H.261, H.263, QCIF/CIF, 4CIF
Audio Coding
(without transcoder card)
G.711 a/µ-law
Audio Coding
(with transcoder card)
G.711 a/µ-law, G.722, G.723.1, G.728, and G.729
Up to 30 calls in videoconferences and up to 60 calls in audio-only conferences.
Data Collaboration
T.120
Panel LEDs
GK Reg (registered with Gatekeeper), CPU High, Alarm, Activity
Module Dimensions
Height: 0.81 in. (2.1 cm)
Width: 9.19 in. (23.34 cm)
Depth: 6.3 in. (16 cm)
Module Types Available
A single module type supports both system (top, slot 1) and add-on (slots 2-4)
positions in the Cisco IP/VC 3544 chassis.
Software Upgrades
Remote software upgrade by administrator using software utility
Table 4
MCU Module Capacity for Voice-Switched Conferences
Number of Participants in Conference(s)
Call Bandwidth 100-Session Module 60-Session Module 30-Session Module
128 Kbps 100 60 30
384 Kbps 70 42 21
768 Kbps 25 15 7
1.5 Mbps 15 9 4
2.0 Mbps 10 6 3
Audio Only 150 90 45
Table 5
MCU Module Capacity for Continuous-Presence Conferences
Number of Participants in Conference(s)
Video Rate (kbps) into MCU
(QCIF)/Out from MCU (CIF)
100-Session Module 60-Session Module 30-Session Module
110/440 66 40 20
320/1280 45 27 13