CHAPTER
Cisco 6200 User Guide 1-1
1
Hardware Description
This chapter provides an overview of the Cisco 6200 advanced digital subscriber line access
multiplexer (DSLAM) and describes the system’s hardware components. The chapter is arranged as
follows:
Cisco DSL Product Family on page 1-1
Cisco 6200 Chassis on page 1-2
Network Trunk Cards (NTCs) on page 1-9
Management Processor Card (MPC) on page 1-18
Subscriber Line Card (SLC) on page 1-22
Warning For translations of the safety warnings in this chapter, see Appendix C, “Translated Safety
Warnings.
1.1 Cisco DSL Product Family
The Cisco 6200 is part of a family of digital subscriber line (DSL) products that provide end-to-end
service, carrying data between the subscriber’s home or office, the telephone central office (CO), and
the networks beyond. The Cisco 6000 family includes the following members:
The Cisco 6200 DSLAM is a CO-grade multiplexer that supports up to 80 asymmetric digital
subscriber line (ADSL) ports. The Cisco 6200 sends and receives subscriber data (often Internet
service) over existing copper telephone lines, concentrating all traffic onto a single high-speed
trunk for transport to the Internet or the enterprise intranet.
ADSL customer premises equipment (CPE) devices, which reside at the subscriber site
connected to PCs or routers, modulate data so that it can travel over telephone lines to the Cisco
6200 DSLAM at the CO. CPE devices in the Cisco DSL product family include the Cisco 675
and the Cisco 605.
The Cisco 6200 Manager is an SNMP-based element management application that provides
configuration, monitoring, and management support. The Cisco 6200 Manager offers a graphical
user interface and runs under Windows NT 4.0 and higher. A separate console interface to the
Cisco 6200 DSLAM provides command line access to all management services.
ADSL plain old telephone service (POTS) splitters, or voice filters, located both at the subscriber
premises and at the CO, support simultaneous voice and data transmission. (If a subscriber is
using a telephone line for data only, the POTS splitter connection is not required.)
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Hardware Description

CHAPTERCisco 6200 User Guide 1-11Hardware DescriptionThis chapter provides an overview of the Cisco 6200 advanced digital subscriber line accessmultip

Seite 2 - 1.2 Cisco 6200 Chassis

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-10Figure 1-5 NTC OC-3 ApplicationThe optical interface performs the optical-to-electr

Seite 3 - 1.2.2 Backplane

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-11The fiber optic communication channels in the single-mode OC-3c card (NTC OC3-SM) o

Seite 4 - Ethernet Management Bus

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-12Table 1-3 LEDs on the NTC OC-3LED Color Condition IndicatedPOWER Green The module i

Seite 5 - Alarm Relay Connection

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-131.3.3 NTC OC-3 SpecificationsTable 1-4 lists the physical and electrical specifica

Seite 6 - Unused Connectors

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-14The NTC STM-1 also transmits upstream data back to the service provider via ATM on

Seite 7 - 1.2.6 DSLAM Specifications

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-15The upstream data transfer unit receives data via a 16-bit parallel input from the

Seite 8

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-16Figure 1-8 NTC STM-1 FaceplatesLED IndicatorsTable 1-5 describes the LEDs on the fa

Seite 9 - Cisco 6200 User Guide 1-9

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-17Table 1-5 LEDs on the NTC STM-11.3.6 NTC STM-1 SpecificationsTable 1-6 lists the

Seite 10 - OC-3c Trunk Port

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-18Table 1-6 NTC STM-1 Specifications1.4 Management Processor Card (MPC)The Cisco 620

Seite 11 - LED Indicators

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-19 The MPC runs a version of Cisco IOS software that is designed for DSL multiplexin

Seite 12

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-2The Cisco DSL family also includes a Frame Relay IDSL multiplexer, a service selecti

Seite 13

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-20Console PortThe console port on the MPC is a serial EIA/TIA-232 port with an RJ-45

Seite 14

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-211.4.3 MPC SpecificationsTable 1-8 lists the physical and electrical specifications

Seite 15 - Cisco 6200 User Guide 1-15

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-221.5 Subscriber Line Card (SLC)This section describes the CAP and DMT versions of

Seite 16

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-23In the downstream direction, 11 rates are available ranging from 640 kbps to 7.168

Seite 17

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-241.5.2 SLC 8CAP: Physical DescriptionUp to 10 SLCs can be installed in a Cisco 620

Seite 18

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-25Table 1-9 SLC 8CAP LEDsLED Color Condition IndicatedPOWER Green The SLC is receivi

Seite 19 - 1.4.2 Physical Description

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-261.5.3 SLC 8CAP SpecificationsTable 1-10 lists the physical and electrical specifica

Seite 20 - Ethernet Port

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-271.5.4 What is the SLC 8DMT?The eight-port DMT version of the SLC (SLC 8DMT) is a

Seite 21 - 1.4.3 MPC Specifications

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-28In the upstream direction, the SLC receives ADSL signals from a POTS splitter and d

Seite 22 - How the SLC Handles Traffic

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-29• Number of upstream cells received with invalid header checksum• Number of errore

Seite 23 - Statistics

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-3Figure 1-1 Cisco 6200 Chassis, Front View1.2.2 BackplaneLocated behind the module

Seite 24

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-30Figure 1-13 SLC 8DMT FaceplateReset SwitchThe reset switch is recessed behind the f

Seite 25

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-31Table 1-11 SLC 8DMT LEDsLED Color Condition IndicatedPOWER Green The SLC is receiv

Seite 26

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-321.5.6 SLC 8DMT SpecificationsTable 1-12 lists the physical and electrical specifica

Seite 27 - 1.5.4 What is the SLC 8DMT?

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-4Figure 1-2 Cisco 6200 Chassis, Rear ViewPrimary (A) and Secondary (B) H-BusesThe bac

Seite 28

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-5Connections to POTS Splitters or Telephone LinesOn the inner surface of the backpla

Seite 29 - Cisco 6200 User Guide 1-29

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-6Auxiliary PortJ40, a 9-pin female connector on the Cisco 6200 backplane, is an EIA/T

Seite 30

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-7The following fixtures are present on the front panel of each PEM:• A green LED that

Seite 31

1 Hardware Description 78-5296-02 10/02/98Cisco 6200 User Guide1-8Table 1-1 Cisco 6200 DSLAM SpecificationsTable 1-2 Standards and CertificationsSpecific

Seite 32

78-5296-02 10/02/98 Hardware Description 1Cisco 6200 User Guide 1-91.3 Network Trunk Cards (NTCs)This section describes the OC-3c and STM-1 network

Kommentare zu diesen Handbüchern