2-34 Receivers 4000326 Rev A
Monitor Status Parameters,
Continued
STATUS Screen Description
The first STATUS screen is called the Summary STATUS screen, and it provides the
following receiver information:
Received optical power level in dBm for RX 1 and RX 2
SMC ID of the receiver
When in the summary STATUS screen, press the Select key on the receiver to
rotate through the remaining parameters.
Each parameter has its own STATUS screen that displays the following information:
The parameter being monitored
The measured level of the parameter being monitored
A FAIL indication for parameters without an operating range that are not working
Assessment of the measured level, against the level required for normal operation,
for items without an operating range
The following table shows the assessments that can be displayed for each measured
item.
STATUS Screen Value Description
OK
The measured level is within the range for normal
operation.
HIGH
The measured level is above the range for normal
operation.
LOW
The measured level is below the range for normal
operation.
FAIL
Component, test, or signal failure (for parameters
without an operating range).
Continued on next page