Cisco UCS C24 M3 High-Density SFF Rack-Mount Server
TECHNICAL SPECIFICATIONS
57
Environmental Specifications
The power specifications for the C24 M3 server are listed in Table 31.
Table 31 UCS C24 M3 Environmental Specifications
Parameter Minimum
Temperature operating 41 to 104° F (5 to 40° C)
derate the maximum temperature by 1°C per every 305m of
altitude above sea level
Temperature nonoperating –40 to 149°F (–40 to 65°C)
Humidity (RH) nonoperating,
non-condensing
10 to 90%
Altitude operating 0 to 3,000 m (0 to 10,000 ft.)
Altitude nonoperating 0 to 12,192 m (0 to 40,000 ft.)
Sound Power level, Measure
A-weighted per ISO7779 LWAd (Bels)
Operation at 73°F (23°C)
5.9
Sound Pressure level, Measure
A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)
46