Cisco WS-C3650-24TS-S Datenblatt Seite 20

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 27
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 19
© 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 20 of 27
Description Specification
IEEE 802.3u 100BASE-TX specification
IEEE 802.3ab 1000BASE-T specification
IEEE 802.3z 1000BASE-X specification
Power Supply Specifications
Table 10 lists the power specifications for the Cisco Catalyst 3650 Series based on the kind of power supply used.
Table 10. Power Specifications for Cisco Catalyst 3650 Series
Description Specification
PWR-C2-1025 WAC PWR-C2-640 WAC PWR-C2-250 WAC PWR-C2-640 WDC
Power Supply Rated Maximum 1025W 640W 250W 640W
Total Output BTU (Note: 1000
BTU per hr = 293 W)
3497 BTU/hr, 1025W 2183 BTU/hr, 640W 853 BTU/hr, 250W 2188 BTU/hr, 640W
Input-Voltage Range and
Frequency
115-240VAC,
50-60 Hz
100-240VAC,
50-60 Hz
100-240VAC,
50-60 Hz
-36VDC to -72VDC
Input Current 12-6A 8-4A 4-2A 21 - 10.5 A
Output Ratings 12V @ 20.83A
-54V @ 14.6A
12V @ 20.83A
-54V @ 7.36A
12V @ 20.83A
12V @ 20.83A
-54V @ 7.36A
Output Holdup Time 10 ms minimum @
102.5VAC
16.7 ms minimum @
100VAC
16.7 ms minimum @
100VAC
> 2ms@-48VDC
Power-Supply Input
Receptacles
IEC 320-C16
(IEC60320-C16)
IEC 320-C16
(IEC60320-C16)
IEC 320-C13 (IEC60320-
C13)
Terminal strip
Power Cord Rating 13A 13A 10A 20A @ 100VDC
Physical Specifications (H x W x D): 1.58 X 3.75 X
13.25 in (4.0 x 9.5 x 33.7
cm)
Weight: 3.55 lb
(1.61 kg)
(H x W x D): 1.58 X 3.75
X 11.75 in (4.0 x 9.5 x
29.8 cm)
Weight: 3.1 lb
(1.41 kg)
(H x W x D): 1.58 X 3.75
X 11.75 in (4.0 x 9.5 x
29.8 cm)
Weight: 2.55 lb
(1.16 kg)
(H x W x D): 1.58 X 3.75
X 11.75 in (4.0 x 9.5 x
29.8 cm)
Weight: 2.75 lb
(1.25 kg)
Operating Temperature For the operating temperature ranges at various altitudes of AC and
DC power supply module powered switches, see Table 1.
Storage Temperature -40 to 158°F (-40 to 70°C)
Relative Humidity Operating
and Non-Operating
Noncondensing
5 to 96% noncondensing
Altitude 16,400 ft. (5,000 meters)
MTBF Calculated MTBF must be greater than 300,000 using Telcordia SR-332, Method 1, Issue 3. Demonstrated
MTBF is 500,000 hr (with 90% confidence level).
EMI and EMC Compliance “AC OK”: Input power to the power supply is OK
“PS OK”: Output power from the power supply is OK
Safety Compliance For the operating temperature ranges at various altitudes of AC and
DC power supply module powered switches, see Table 1.
LED Indicators -40 to 158°F (-40 to 70°C)
Power Consumption of Standalone Cisco Catalyst 3650 Series Switches
Table 11 shows power consumption of standalone Cisco Catalyst 3650 Series Switches based on Alliance for
Telecommunications Industry Solutions (ATIS) testing using IMIX distribution stream traffic, with input voltage of
115VAC @ 60 Hz, Energy Efficient Ethernet (EEE) enabled, and no PoE loading. The values given are the
maximum possible power consumption numbers under the respective test scenarios.